Your specialist for Energy Management Systems and measurement technology.
|
| Employees : |
20+ |
| Year established : |
1983 |
Business : |
Manufacturer |
Your specialist for Energy Management Systems and measurement technology. Since 1983 we are one of the leading manufacturers of Measuring- and Testing Systems for the energy and environmental technology. Our Energy Management Systems are used successfully worldwide.
With the software for the analysis of the energy flow hidden energy saving-potentials are made visible. Peak load optimization for current, gas, water, long-distance heating etc. makes it possible for every enterprise to lower its energy costs.
| CKS - Current Switch Inputs: Current 0 - 40(60) A direct, max. 230 VAC, Net frequency: 50 Hz,peak-value-factor: max. 2, Outputs: Relay Output 1 Changer, 3A, 250 VAC or 30 VDC Interfaces: Serial interfaces 1; 3,3 V-level (with optional adapters for RS232) |
| EKM - Energy-Control-Module Low cost energy control system for the peak load optimization!
The EKM is an optimization computer which get its information from the counter of the energy supplier. The calculation is based on the trend procedure.
With the simultaneous recording of the consumption values, the EKM knows every time, how much energy is used in the current measurement period and how much energy is still available in the remaining time of the measurement.
Before the maximum limit is reached, the EKM switch off the preselected consumer loads. The consumer loads will be switched on at the latest timepoint and only if it is absolute essential for the production process or the machine-living. The deactivation of the machines depends on an pre-defined sequence. If the Switching-strategy is correct selected, the production process will not be constricted. The switchings have no effect on the production process and they guarantee a maximum of cost reduction.
|
| Energy Control Systems With us you get your energy costs under permanent control
The Energy Control System EKSC4 made by RSW Technik is an optimization computer and works according to the trend procedure.
The optimization computer obtains its information about the energy consumption through the provider counter. While synchronously recording the consumption, the optimization computer registers at any time the amount of energy used during the measuring period as well as the remaining energy available in the balanced time of the measuring period.
In case the maximum limit impends to exceed the EKS switches either off preselected consumers or reduces the output if the consumer can be regulated by the set point of an external set value. The consumers are switched at the latest possible time and only then if it is absolutely necessary. The switching off is done according to predetermined order. If the switching strategy is correctly chosen the production sequence is not restricted. The switching operations remain unnoticed and guarantee a maximum saving.
| |
|
Energy Control Systems
Click on our Logo to view this Catalog
|
|
|
|
|