"Hanovia has been manufacturing UV Lamps, Power Supplies and Reflector Assemblies since 1905 |
| Year established : |
1905 |
Business : |
Manufacturer |
"Hanovia has been manufacturing UV Lamps, Power Supplies and Reflector Assemblies since 1905. A long term member and supporter of RadTech and the SGIA, Hanovia is a global manufacturer providing equipment to the printing, coating, and adhesive industries.
Hanovia also produces photochemical equipment consisting of turn key systems, and custom designed systems used in the pharmaceutical and fine chemical industries.
Industrial based air/water sterilization products and photoluminescent pigment/vinyl products used in the safety, education and novelties markets round out the product mix".
| Conveyorized UV System Advanced Features That Put Hanovia Way Above The Rest Efficiency, reliability and simplicity are designed into every Hanovia UV curing system – systems that enjoy a worldwide reputation as cost effective equipment for curing a wide variety of photocurable products. These latest Hanovia UV curing systems require less floor space, provide better accessibility and easier maintenance. UV Conveyorized System Technical features include: • Replaceable reflector elements • No-tools lamp change • Multi-level lamp power • Vacuum hold down • Adjustable curing chamber entrance opening • Adjustable speed conveyor • Individual lamp controls • Lamp height adjustment All Hanovia UV curing systems are available with multiple lamps according to your production needs. Hanovia’s more than ninety years of experience brings quality engineering and safety features to every product. And no matter what the need, there’s a Hanovia product to meet it. |
| Luxor Alpine Quartz Lamp The Hanovia Luxor Alpine Quartz Lamp provides the practitioner with Full Spectrum Ultraviolet, Health, Germicidal, and Therapeutic Rays PLUS 400 Watts of Infrared Radiation for fast and efficient office and hospital therapy Features: • 25-Second Exposure - produces 1st degree erythema at 30" • Lamp Builds Up Quickly - to full intensity • Built-In - tape measure assures consistent patient positioning in relation to source • Quick Cooling - permits fast relighting • Intense Output - evenly distributed over wide, shadowless area • Fully Adjustable - to every position • Independent Operation - of infrared and ultraviolet generators • Rugged Design - assures years of dependable service Specifications Operates on: • 110-120 Volts, 60 Cycle AC • 220 Volts, 50 Hz AC • Input: 560 Watts; 6 Amperes Ultraviolet Source: Self-starting, high-pressure pure quartz mercury arc tube equipped with activated thermionic electrodes. Metal leads sealed directly in quartz. 135 Volts; 450 Watts; 4 Amperes. Average Output at 30" • with shutters vertical - 5100 Microwatts per sq. cm. • with shutters horizontal - 2900 Microwatts per sq. cm. Infrared Source: Two 200-Watt generators enclosed in quartz tubes...operated independently of ultraviolet type. 400 Watts. |
| Room Air SanitizerRoom Air Sanitizer Method of Operation In STERILAIRE™ Room Air Sanitizers room air is drawn past washable electrostatic filters, then forced into an ultraviolet exposure chamber in which the air is subjected to powerful germicidal rays, past baffles and then reintroduced into the room. The STERILAIRE Room Air Sanitizer provides effective germicidal treatment without the hazards associated with exposed ultraviolet lamps. Application of equipment is simple and straightforward. Selection: In selecting your STERILAIRE Room Air Sanitizer several factors should be considered. STERILAIRE Room Air Sanitizers are selected to treat a given area based on the equipment room air changes per hour that the STERILAIRE Room Air Sanitizer is capable of treating. To tread areas that are normally or well ventilated, we recommend selection of a STERILAIRE Room Air Sanitizer that will yield a minimum of three (3) equivalent room air changes per hour. In areas that are poorly ventilated and areas that present a higher than usual risk of airborne infection (such as a crowded waiting room), installation of a STERILAIRE Room Air Sanitizer capable of six (6) equivalent room air changes per hour is recommended. To select the appropriate STERILAIRE Room Air Sanitizer(s), first determine the desired number of equivalent room air changes per hour. Then calculate the total cubic feet per hour required to yield the desired number of equivalent room air changes using the following formula: Room Size (cubic feet) x Room Air Changes = Cubic Feet per Hour Once the volume of the area to be treated is known, Tables 1 and 2 can be used to select the most suitable STERILAIRE Room Air Sanitizer for your application. |
| UV Curing Assemblies Our Reflector Assemblies are Feature Packed for Any Application • Lightweight extruded aluminum housing • ARC lengths from 4" to 77" • All extruded construction allows operation up to 400 w/in • Air-cooled from either end or center • Adaptable for use with dichroic optics (coated reflector/quartz plate) • Can be used with ceramic or metal end lamps • Available with focused or flood reflector |
| UV Radiometer New Hanovia Radiometer measures Mj/cm2 in UVA,B,C and V FUNCTIONS: Measures UV Lamp efficiency & curing system performance. Applications: UV Conveyors, Graphic Arts Equipment, Printed Circuit Board Exposure Equipment and other UV curing systems. |
| Water Purifier Ultraviolet/Germicidal water purification systems Ultraviolet/Germicidal water purification systems from Hanovia... ...provide a fast, unique way to disinfect water without heat or chemicals. Using short-wave radiation from Hanovia germicidal ultraviolet lamps, STERITRON purifiers destroy all water-borne microorganisms, including bacteria and viruses. Hanovia germicidal lamps are found in a variety of applications, including personnel protection and prevention and prevention of cross infection in hospitals, laboratories and veterinary facilities and product contamination prevention in the food processing, pharmaceutical, bottling, electronics and semiconductor industries. How the system operates: • Water enters purifier and flows into annular space between quartz sleeve and outside chamber wall. • Wiper segments induce turbulence in flowing liquid to ensure uniform exposure of suspended microorganisms to lethal ultraviolet rays. • Translucent sight port provides positive indication of germicidal lamp operation • Wiper assembly facilitates periodic cleaning of quartz sleeve without disassembly or interruption of purifier operation. • Water leaves purifier ready for use instantly. | |
|
|
|
|